Single phase, three phase or VFD: industrial cooler power options

Choose single phase if your site has only a 220 V supply, and three phase if 415 V is available, especially for larger coolers. Add a VFD if the cooler will run long hours and you want speed control. Always fit a phase preventer on a three-phase cooler to protect the motor.

What our duct coolers offer

Model Motor Single phase 220 V Three phase 415 V
18,000 CMH 1.1 kW Yes Yes
22,000 CMH 1.5 kW Yes Yes
25,000 CMH 2 kW Yes Yes
30,000 CMH 3 kW Yes Yes
50,000 CMH 4.5 kW No Yes

Single phase

  • Works on the supply most shops, small workshops and offices already have
  • Simple to connect
  • Best for the smaller models and for one or two coolers

Three phase

  • The standard supply in factories and warehouses
  • Shares the load evenly across three lines, which suits larger motors
  • Needed for the 50,000 CMH model
  • Must be protected against phase failure

Why a phase preventer matters

If one of the three phases drops out or the voltages go out of balance, the motor keeps trying to run, overheats and burns out within minutes. A controller with a phase preventer cuts the power first. Our 1-year motor warranty applies only when one is fitted.

What a VFD does

A variable frequency drive changes the motor speed smoothly from a wall display or remote.

  • Lower power use when full airflow is not needed, such as mornings, evenings and mild days
  • Less noise at reduced speed
  • Softer starts, which are easier on the motor and belt-free fan

A VFD costs more at the start; it pays back fastest on coolers that run many hours a year. See the VFD kit, available from 1.1 to 4.5 kW.

Quick guide

Your site Choose
Shop or small workshop, 220 V only Single-phase 18,000 to 25,000 CMH
Factory with 415 V Three phase with phase preventer
Long running hours, changing weather Add a VFD
Very large floors Three-phase 50,000 CMH

Frequently asked questions

Can an industrial cooler run on single phase?

Yes. Our 18,000 to 30,000 CMH coolers are available in single phase; the 50,000 CMH model is three phase only.

Is a VFD necessary for an air cooler?

Not necessary, but it saves power and noise when the cooler runs below full speed for many hours.

Why does a three-phase cooler need a phase preventer?

Because a phase failure makes the motor overheat and burn out; the preventer cuts power in time.